Technical Specifications 5-BAND-EQ STEREO W789
Size Stereo V700 Module 1N

Input
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level +6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT

Output
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 40 W
Load Resistance ³ 300 W
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT

Gain 2) all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB

Frequency Response 2) ƒ 20 Hz - 20 kHz ± 0.75 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
with Standard Values for RF & LF Filters

THD £ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %

Dynamic Range 2) 22Hz-22kHz RMS ³ 120 dB
Noise Level 2) 22Hz-22kHz RMS £-90 dBu

Crosstalk L <> R ƒ 40 Hz - 15 kHz £ - 70 dB

Size V700 Module, standard Depth
Frame fits into Standard Frames


Control Elements

Stepper Pot

Boost/Cut Range max. ± 24 dB ± 1.5 dB with Center Detent at 0 dB
Frequency HI
switchable 18 kHz Baxandall
10 kHz Soft-Bell
Frequency MID3 250 Hz to 25 kHz ± 10 %
Frequency MID2 60 Hz to 7 kHz ± 10 %
Frequency MID1 20 Hz to 2 kHz ± 10 %
Frequency LOW switchable 60 Hz / 100 Hz - Soft-Bell
Q-Factor for MID1, MID2 and MID 3 > 3 Octaves to a Third
Bypass

with Push Button EQ-ON



1) Depending on the setting of the control, gain or attenuation is possible. The value is valid for the higher level at the input or output.

2) The values refer to precisely linear setting of all parameters.

Index Home V700 Home