CLOSE
Technical Specifications Stereo Mastering Highpass -Lowpass Filter with Phasen Correction W790
Size Stereo V700-Module 1N

Input
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT

Output
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 40 W
Load Resistance ³ 300 W
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT

Gain 2) all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB

Frequency Response 2) ƒ 20 Hz - 20 kHz ± 0.5 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
with Standard Values for RF & LF Filters

THD £ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %

Dynamic Range 2) 22Hz-22kHz RMS ³ 120 dB
Noise Level 2) 22Hz-22kHz RMS £-90 dBu

Crosstalk (at W792) L <> R ƒ 40 Hz - 15 kHz £ - 70 dB

Size V700 Standard Module Size, standard Depth
Frame fits into Standard Frames

Control Elements
Stepper Pot
HPF/LPF maximum Flat-Filter 2nd Order with 12 dB/Oct
switchable to 6 dB/Oct.
Range LPF > 100 kHz to 8 kHz
Range HPF < 5 Hz to 100 Hz

Phase Correction multi stage Allpass Filter
High
Control Range from 8 kHz to 100 kHz
Low
Control Range from 5 Hz to 100 Hz
Characteristics
adapted to correcting the HPF/LPF Filter
switchable to 1st Order Filter

Bypass

single Bypass-Swtiches


1) Depending on the settings of the control elements, attenuation is possible. The value refers to the highest level on input or output

2) Refers to linear adjustment of all parameters

Index Home V700 Home