Technical Specifications |
Stereo Mastering Highpass -Lowpass Filter with Phasen Correction W790 |
Size |
Stereo V700-Module 1N |
|
Input |
|
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz ³ + 30 dBu |
Input Impedance |
ƒ 40 Hz - 15kHz ³ 5 kW |
CMRR |
ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT |
|
Output |
|
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu |
Source Impedance |
ƒ 40 Hz - 15 kHz £ 40 W |
Load Resistance |
³ 300 W |
CMRR |
ƒ £ 15 kHz ³ 40 dB according to IEC |
CMRR |
ƒ £ 15 kHz ³ 60 dB according to IRT |
|
Gain 2) |
all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB |
|
Frequency Response 2) |
ƒ 20 Hz - 20 kHz ± 0.5 dB |
Phase Response 2) |
- Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
- with Standard Values for RF & LF Filters
|
|
THD |
£ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 % |
|
Dynamic Range 2) |
22Hz-22kHz RMS ³ 120 dB |
Noise Level 2) |
22Hz-22kHz RMS £-90 dBu |
|
Crosstalk |
(at W792) L <> R ƒ 40 Hz - 15 kHz £ - 70 dB |
|
Size |
V700 Standard Module Size, standard Depth |
Frame |
fits into Standard Frames |
|
Control Elements |
- Stepper Pot
|
HPF/LPF |
maximum Flat-Filter 2nd Order with 12 dB/Oct
switchable to 6 dB/Oct. |
Range LPF |
> 100 kHz to 8 kHz |
Range HPF |
< 5 Hz to 100 Hz |
|
Phase Correction |
multi stage Allpass Filter |
High |
- Control Range from 8 kHz to 100 kHz
|
Low |
- Control Range from 5 Hz to 100 Hz
|
Characteristics |
- adapted to correcting the HPF/LPF Filter
switchable to 1st Order Filter
|
|
Bypass |
single Bypass-Swtiches
|
|
1) |
Depending on the settings of the control elements, attenuation is possible. The value refers to the highest level on input or output |
|
2) |
Refers to linear adjustment of all parameters |
|
Index |
Home V700 Home |