CLOSE
Technical Specifications 4 BAND EXTENSION FOR
STEREO MASTERING EQUALIZER W798
Size V700- Double-Wide Module 2N
only in Combination with Stereo Mastering Equalizer W796 as 4 Band Extension
requires Modification in W796

Input stereo
Type balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT

Output stereo
Type balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 50 W
Load Resistance ³ 2 kW
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT

Gain 2) all Controls at 0 dB Position
1 kHz 0 dB ± 0.5 dB

Frequency Response 2) ƒ 20 Hz - 20 kHz ± 0.5 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5/-20°
with Standard Values for RF & LF Filters

THD £ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %

Dynamic Range 2) 22Hz-22kHz RMS ³ 120 dB
Noise Level 2) 22Hz-22kHz RMS £-90 dBu

Crosstalk L <> R ƒ 40 Hz - 15 kHz £ - 70 dB

Size V700 double-wide Module, standard Depth
Frame needs 2 Frame Compartments

Control Elements
Stepper Pot
Boost/Cut Range max. ± 15 dB ± 1 dB with Center Detent at 0 dB
Frequency HI 2 kHz to 31.5 kHz ± 10 %
Frequency HI-MID 1.5 Hz to 20 kHz ± 10 %
Frequency L-MID 250 Hz to 3.75 kHz ± 10 %
Frequency LOW 40 Hz to 630 Hz ± 10 %
Q-Factor > 2 Octaves to a Third
Bypass
hard bypass for the entire Units and
Bypass per EQ-Band
Level fixed
Balance fixed

1) Depending on the setting of the control, gain or attenuation is possible. The value is valid for the higher level at the input or output.

2) The values refer to precisely linear setting of all parameters.