Technical Specifications ToolMod TM107 3 Band Equalizer |
|||
|
|||
Format | ToolMod Module Size 2U | ||
Versions | TM107-20h - +/- 20 dB, horizontal Face Plate TM107-20v - +/- 20 dB, vertical Face Plate TM107-12h - +/- 12 dB, horizontal Face Plate TM107-12v - +/- 12 dB, vertical Face Plate |
||
Power Supply | Tool-Series Standard | ||
Supply Voltages | +/- 25 V and + 48 V Phantom | ||
Supply Current *) | +/- 100 mA | ||
Input | electronically balanced | ||
nominal Level | + 6 dBu - Gain | ||
maximum Level | > + 30 dBu - Gain | ||
Input Impedance | 40 Hz - 15 kHz > 10 kOhms | ||
nominal Source Impedance | 50 Ohms | ||
CMRR | 15 kHz > 65 dB, typical 75 dB 1 kHz > 80 dB, 40 Hz > 90 dB | ||
Output | electronically balanced | ||
nominal Level | + 6 dBu | ||
maximum Level | > + 30 dBu | ||
Source Impedance | 50 Ohms, see Diagram Output Source Resistance vs Frequency |
||
Load Resistor | see Diagram maximum Output Level vs Load Resistor and maximum Output Level vs capacitive Load |
||
CMRR according to IEC | > 40 dB, siehe Diagram Output CMRR vs Frequency | ||
Gain | 0 dB +/- 0.3 dB linear setting | ||
Frequency Response |
20 Hz - 30 kHz +/- 0.75 dB linear setting | ||
Bandwidth | < 10 Hz to > 150 kHz | ||
Phase Response | 20 Hz-20 kHz < +6/-10° linear setting - see Diagram Phase Response |
||
THD | < + 28 dBu, 40 Hz ... 20 kHz, < 0.1 %, maximum THD at + 30 dBu <1 % |
||
Dynamic Range / Noise | |||
RMS 22Hz-22kHz | <= -91 dBu linear setting | ||
total Dynamic Range | referring to the RMS Value 22Hz-22kHz >= 121 dB linear setting |
||
High EQ | active RC-Filter with Shelving Characteristics with Frequency Control from 1 kHz to 40 kHz and Steepness 6 dB/Oct. - 12 dB/Oct., selected by switch Control Range +/- 20 dB or +/- 12 dB,depending on Version |
||
Low EQ | active Vienna Bridge Filter Bell Characteristics with Center Frequency Control 15 Hz to 400 Hz +/- 15 % and Q-Factor Q = 0.5 and Q = 2, selected by switch Control Range +/- 20 dB or +/- 12 dB, depending on Version |
||
Mid EQ | fully parametric Equalizer Band with active Vienna Bridge Circuitry, with Center Frequency Control from 100 Hz +/- 10 % to 10 kHz, +/- 15 % Q-Factor Control from > 3 Octaves to a Third Control Range +/- 20 dB or +/- 12 dB, depending on Version |
||
Bypass Circuitry | Hardbypass by Relay | ||
*) The standard supply current is the supply current under realitic operation conditions. If the outputs are loaded with the minium load resistors and the level is at + 30 dBu, the supply current increases by 30 mA per output. The standard supply current shuold be used to calculate the necessary power supply capacity of a system. | |||